Integrated Environment Requirements
Integrated site requirements: Machine external dimensions<2600 (height) x 1700 (length) x 1200 (width) mm (excluding rocker arm) Integrated site requirements: 2700mm (length) * 2200mm (width) 2 Operating environment requirements: Clean room Class10003 Ground requirements: flatness<2mm/m, water sub degree<2mm/m45 Environmental temperature and humidity: 20~26C, 35%~60% RH Power supply: three-phase 5-wire system, 380V 50Hz, 30A;
Overall acceptance standards
1. Confirm that all self inspection items of the machine meet the requirements and have complete records. 2. Confirm that all inspection items of the machine pipe line are qualified and have complete records; 3. Confirm that the inspection items in the machine value table are qualified and the records are complete;
4. Confirm that the machine warning label and safety identification inspection items are qualified; 5. The general quality inspection and self inspection of the machine meet the requirements and the records are complete;
6. Conduct functional performance acceptance according to the STPS document of the product. If all indicators meet the requirements, it is qualified. Conduct product acceptance according to the general quality inspection specifications of the product. If all inspections meet the requirements, it is qualified